An efficiently functioning pool water circulation and filtration system is the core lifeblood of a swimming pool to maintain its crystal quality. This article teaches you how to become an "internist" in pool health management, from equipment anatomy, cycle maintenance to avoiding pitfalls!
▍系统核心组件「生命体征监测表」
❶ Sand tank filters - the heart of water purification
▸ Health indicators: pressure gauge ≤ 1.5 bar, pressure drop after backwash ≥ 0.3 bar
▸ Abnormal signals: persistent turbidity in the viewing window/hardness of the filter media plates
❷ Circulating pumps - power source for water circulation
▸ Health indicators: operating current ≤ rated 10%, no high-frequency rattles
▸ Death warning: Bearing temperature > 75°C/water dripping at seals
❸ Sterilization systems - microbial firewalls
▸ Ideal: Residual chlorine value 1-3ppm, ORP ≥ 650mV
▸ Imbalance Alert: Chemical Chlorine >0.2ppm/Cyanuric Acid Exceedance
▍分级养护时间表(以标准家用泳池为例)
🔧 Daily Essentials
√ Check for fluctuations in pressure gauge/flow meter values
√ Fishing for floating debris on the water surface (leaves/sunscreen film)
√ Visual inspection of pool walls for signs of algae growth
🔧 Weekly intensive care
→ Backwash sand tanks (until the water is clear in the observation window)
→ Cleaning of hair traps (silicone grease lubricated seals)
→ Calibration of water quality sensors (using standard reagents)
🔧 Quarterly systematic medical examinations
✧ Dismantling and inspection of the filter media layer: replenishment of 10% new quartz sand
✧ Water pump maintenance: replacing mechanical seals/lubricating bearings
✧ Pipeline inspection: ultrasonic detection of hidden cracks
ralph lauren seasonal protection guide
☀️ Summer Heat Combat Kit
❶ Twice daily water quality tests (recommended 7:00 & 16:00)
❷ Additional UV sterilizer (breaks down sunscreen contaminants)
❸ Cycle time extended by 2 hours (midnight mode recommended)
❄️ Winter Dormancy Program
❶ Fill with antifreeze after draining the 90% water body
❷ Remove gauge/transducer for indoor storage
❸ Electrothermal "warm clothes" for pipes
⚠️ Eight life-compromising operations blacklisted
❗ Direct cleaning of canisters with hydrochloric acid (special filter media cleaner should be used)
❗ Prolonged over-pressure operation (exceeding the red mark for more than 10 minutes)
❗ Mixing different brands of disinfectants (prone to toxic fumes)
❗ Neglect of calcium hardness balance (200-400 ppm should be maintained)
ralph lauren polo ralph lauren outlet
✅ IoT monitoring system: real-time view of TDS/turbidity values on your cell phone
✅ Automated Dosing Robot: Linked ORP Sensor for Precise Dosing
✅ Self-cleaning filter: AI recognizes media saturation to initiate backwashing
🔑 The Ultimate Maintenance Philosophy
"Three parts equipment, seven parts maintenance" - each time you invest 1 yuan in maintenance costs, you can save 8 dollars in maintenance costs, extending the life of the equipment 5-8 years!